Camera systems
-
Home alarms
-
PARADOX
-
Paradox DIGIPLEX EVO
- The SPECTRA paradox
- The MAGELLAN Paradox
- Paradox detectors
-
Paradox Wireless Elements
- Paradox Additional resources
- Paradox Communicators
- Signaling
- Tools / Converters
- Detectors from other manufacturers
- Communicators from other manufacturers
- Accessories
-
Paradox DIGIPLEX EVO
-
JABLOTRON
- JA-100 Switchboard Jablotron
- Jablotron Sets
-
Jablotron Detectors
- Jablotron Sirens
- Jablotron Output modules and indicators
- Jablotron Drivers / chips / key fobs / cards
- Jablotron Keyboard + readers
- Jablotron Communicators
- Jablotron Video verification Jablotron
- Jablotron Thermostats
- Jablotron Tools
- Jablotron Accessories
- Jablotron Thermohead
- AJAX
- HIKVISION AX PRO
- DAHUA
-
PARADOX
-
Input systems
- Power supplies
- Measuring devices
- Accumulators / batteries
- Misting systems
- Data networks
- LOXONE Smart home
- Cables
- Tools
- Parts for pumping stations
- Parts for grease separators
- Sale
- Advertising LED Banners
- Inspection cameras
- Home alarms
-
- PARADOX
- JABLOTRON
- JA-100 Switchboard Jablotron
- Jablotron Sets
- Jablotron Detectors
- Jablotron Sirens
- Jablotron Output modules and indicators
- Jablotron Drivers / chips / key fobs / cards
- Jablotron Keyboard + readers
- Jablotron Communicators
- Jablotron Video verification Jablotron
- Jablotron Thermostats
- Jablotron Tools
- Jablotron Accessories
- Jablotron Thermohead
- AJAX
- HIKVISION AX PRO
- DAHUA
- PARADOX
New products
BELL-TEC MINI backup outdoor siren
Hikvision DS-3E0105P-E/M(B) 5/4 PoE switch, 4x PoE...
PARADOX MG5050 panel - 868 2x5, 10 zones, max. 32 zones, on board 4xPGM
The MAGELLAN mixed-type security control panel is intended for small to medium-sized applications. The control panel is already fitted with a 433/868MHz wireless receiver on the board and this predetermines it for wireless installations. In addition to this possibility of connecting sensors, the board has the option of using 2 or 5 inputs with the possibility of connecting 4 or 10 NC zones in the ATZ connection. The control panels can be divided into two subsystems and 32 user codes / wireless key fobs can be used to control the system. Part of the switchboards is a telephone communicator intended for communication on a PCO or on a public telephone.
Our privacy policy
Our Privacy Policy explains our principles when it comes to the collection, processing, and storage of your information. This policy specifically explains how we employ cookies, as well as the options you have to control them.
-
1 What are cookies?
Cookies are small pieces of data, stored in text files that are stored on your computer or other device when websites are loaded in a browser. They are widely used to "remember" you and your preferences, either for a single visit or for multiple repeat visits
-
2 How we use cookies
We use cookies for a number of different purposes. Some cookies are necessary for technical reasons; some enable a personalized experience for both visitors and registered users; and some allow the display of advertising from selected third party networks.
-
3 Controlling Cookies
Visitors may wish to restrict the use of cookies or completely prevent them from being set. If you disable cookies, please be aware that some of the features of our service may not function correctly
-
4 Information We Collect
We only collect information about you if we have a reason to do so-for example, to provide our services, to communicate with you, or to make our services better.
We are committed to maintaining the trust and confidence of our website visitors. We do not collect, sell, rent or trade email lists or any data with other companies and businesses. Have a look at our Privacy Policy page to read detail information on when and why we collect your personal information, how we use it, the limited conditions under which we may disclose it to others and how we keep it secure.
We may change Cookies and Privacy policy from time to time. This policy is effective from 24th May 2018.
To turn on StayD: | Yes |
Division into areas: | yes, 2 |
Direct connection with a PC via the I307 interface: | Yes |
Max. number of zones in the system: | 32 |
Number of inputs (zones) on the control panel board: | 5 (ATZ 10) |
Number of zones on expanders (APR-ZX8): | 24 |
Max. number of keyboards in the system: | 15 |
PGM outputs on the control panel: | 4 x opto-relay 50 mA polarity +/- |
Relay output on the control panel: | No |
Number of user codes: | 32 |
Event history: | 256 |
Power supply: | 16 V~, 20/40 VA |
Source Type: | switched |
Max. current consumption from the AUX output: | 1 A |
AUX output type: | electronic reversible fuse 1.1 A |
Max. current consumption from the BELL output: | 2 A |
BELL output type: | electronic reversible fuse 3 A |
Power consumption of the control panel: | 100mA |
Max. number of keyboards in the system: | 15 |
Maximum bus length /total/: | 230 m |
Maximum length of the bus to the module: | 75 m |
Firmware: | stored in the processor's EEPROM memory |
Firmware change: | yes, using the WinLoad software |
Event history: | 256 |
View event history: | WinLoad software, |
on the K32LCD CZ keyboard | |
Backup battery charging current: | 350/700mA |
Recommended backup battery: | 12V, 7Ah/18Ah |
Optical signaling: | LED CHARGE, STATUS |
Hard reset: | yes, the reset button |
Recommended transformer type: | covered transformer 40 VA |
Recommended box type: | BOX M-40, BOX S-40, BOX VZ-40 |
Number of inputs on the control panel board: | 5 |
Max. number of zones on the panel board: | 10 |
Max. number of zones on keyboards: | 15 (one keypad - one zone) |
Zone Expander: | yes, 8 zones one expander |
Max. number of zone expanders: | 3 |
Bus detectors: | No |
Wireless zones: | yes, 32 |
Types of programmed zones: | 22 |
Definition of dependent / intelli zone: | Yes |
Max. number of keyswitch inputs: | 5, only inputs on the switchboard |
Max. number of PGM outputs in the system: | 16 |
Wireless PGM outputs: | yes, 16 |
Number of subsystems: | 2 |
To create a common area: | No |
Common zones for both subsystems: | Yes |
Master code: | 1 + 2 |
Maintenance code: | 1 |
User codes: | 30 |
Installation code: | 1 |
User code length: | 4 or 6-seater |
Option to control the system: | user code, |
wireless key fob, | |
WinLoad software, keyswitch, | |
web browser - IP100, | |
remotely via a VDMP3 telephone line | |
Automatic power on: | yes, according to the time, calm v system |
Power On Types: | full, FORCE, STAY, SLEEP |
To turn on StayD: | Yes |
Number of telephone numbers on the PCO: | 2 + 1 backup |
Number of telephone numbers per public telephone: | 5 |
Telephone line detection: | Yes |
Communication formats: | Ademco slow, |
Silent Knight fast, | |
Sesco, | |
ademco express, | |
Ademco Contact ID, | |
message on the phone | |
Keyboard: | K10V/H, K32, K32LCD, |
K35, K37, K636, K32RF | |
Software: | WinLoad |
Method of connecting the PC to the control panel: | I307 - RS232/USB, |
modem - telephone line, | |
modem - ADP-1 simulator, | |
IP100 - LAN/Internet | |
Winload: | program for installation, |
management and maintenance | |
Programming method: | from the keyboard or SW WinLoad |
Wireless key fob control: | Yes |
Number of key fobs in the system: | 32 |
Type of keychains: | REM1, REM15, REM2, REM3 |
Wireless detectors: | Yes |
Surveillance of wireless detectors: | Yes |
Surveillance Interval: | 80 minutes/24 hours |
Max. number of wireless detectors: | 32 |
Types of wireless detectors: | all types of wireless |
detectors of the K series | |
Range Extender Repeater: | yes, RPT1 |
Max. number of signal repeaters: | 2 |
Wireless PGM output: | yes type 2WPGM |
Max. number of wireless PGMs: | 16 |
Activation of the PGM output with the key fob: | yes, any PGM in the system |
Wireless keyboard: | yes, K32RF, K37 |
Max. number of wireless keyboards: | 8 |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent

The MAGELLAN mixed-type security control panel is intended for small to medium-sized applications. The control panel is already fitted with a 433/868MHz wireless receiver on the board and this predetermines it for wireless installations. In addition to this possibility of connecting sensors, the board has the option of using 2 or 5 inputs with the possibility of connecting 4 or 10 NC zones in the ATZ connection. The control panels can be divided into two subsystems and 32 user codes / wireless key fobs can be used to control the system. Part of the switchboards is a telephone communicator intended for communication on a PCO or on a public telephone.